flex7 Applications – PELV Occupancy Control
![flex7 applications PELV Occupancy Control flex7 applications PELV Occupancy Control](https://www.flex7.co.uk/wp-content/uploads/2021/07/flex7-applications-PELV-Occupancy-Control.png)
![Wiring Diagrams flex7 Lighting Distribution Box Wiring Diagrams flex7 Lighting Distribution Box](https://www.flex7.co.uk/wp-content/uploads/2021/07/Wiring-Diagrams-flex7-Lighting-Distribution-Box-01.png)
DESCRIPTION | PART NO. |
---|---|
1 X Starter Distribution Box | FSU08 |
1 X Sensor Kit | FNS1200 |
4 X Standard (on/off) luminaire leads | FL3100LSHF5/W |
2 X Maintained Emergency Luminaire Lead | FL4100LSHF5/R |
Control of the luminaires is via a flex7 plug-in sensor head operating at PELV. The luminaires are automatically switched on when movement is sensed. After the room is vacated the luminaires switch off when the timeout period has elapsed.
Installation time is dramatically reduced as everything plugs-in, meaning only the 4 conductors at the Distribution Box require on-site termination.
Note: emergency luminaires are tested via a hard-wired 230V key switch, often located in close proximity to the distribution board.